Intravenous contrast material administration at high-pitch dual-source CT pulmonary angiography: test bolus versus
J Matthias Kerl1, Thomas Lehnert, Boris Schell
1Institute for Diagnostic and Interventional Radiology, Clinic of the Goethe University, Theodor-Stern-Kai 7, 60590 Frankfurt, Germany. matthias.kerl@gmail.com
Purpose:
To compare test bolus and bolus tracking for the determination of scan delay of high-pitch dual-source CT pulmonary angiography in patients with suspected pulmonary embolism using 50 ml of contrast material.
Materials And Methods:
Data of 80 consecutive patients referred for CT pulmonary angiography were evaluated. All scans were performed on a 128-channel dual-source CT scanner with a high-pitch protocol (pitch 3.0, 100 kV, 180 mAs). Contrast enhancement was achieved by injecting 50 ml of iomeprol followed by a saline chaser of 50 ml injected at a rate of 4 ml/s. The scan delay was determined using either the test bolus (n=40) or bolus tracking (n=40) technique. Test bolus required another 15 ml CM to determine time to peak enhancement of the contrast bolus within the pulmonary trunk. Attenuation profiles in the pulmonary trunk and on segmental level as well as in the ascending aorta were measured to evaluate the timing techniques. Additionally, overall image quality was evaluated.
Results:
In all patients an adequate and homogeneous contrast enhancement of more than 250 HU was achieved in the pulmonary arteries. No statistically significant difference between test bolus and bolus tracking was found regarding attenuation of the pulmonary arteries or overall image quality. However, using bolus tracking 15 ml CM less was injected.
Conclusion:
A homogeneous opacification of the pulmonary arteries and sufficient image quality can be achieved with both the bolus tracking and test bolus techniques with significant lower contrast doses compared to conventional contrast material injection protocols.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies VII: Vascular Imaging
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care