Related Experiment Video
Updated: May 28, 2026

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
Analysis of pulsatile and nonpulsatile blood flow effects in different degrees of stenotic vasculature
Jae Seung Jung1, Kuk Hui Son, Chi Bum Ahn
1Department of Thoracic and Cardiovascular Surgery, Anam Hospital, Korea University Medical Center, Seoul, Korea.
Abstract:
Vessel lumens that have been chronically narrowed by atherosclerosis should be increased in flow velocity and intrastenotic area pressure to maintain an equal flow. This might be followed by a decrease in hemodynamic energy, leading to a reduction of tissue perfusion. In this study, we compared hemodynamic energies according to degrees of stenotic vasculature between pulsatile flow and nonpulsatile flow. Cannuale with 25, 50, and 75% diameter stenosis (DS) were located at the outlet cannula. Using the Korea Hybrid ventricular assist device (KH-VAD) (pulsatile pump: group A) and Biopump (nonpulsatile pump: group B), constant flow of 2 L/min was maintained then real-time flow and velocity in the proximal and distal part of the stenotic cannula were measured. The hemodynamic energies of two groups were compared. At 75% DS, proximal energy equivalent pressure (EEP) delivered to the distal end was only 41.9% (group A) and 42.5% (group B). As the percent EEP fell below 10%, pulsatility disappeared from the 50% stenosis in group A. The surplus hemodynamic energy (SHE) of group B at all degrees of stenosis must have been 0, which was also the case of group A at 75% stenosis. This research evaluated the hemodynamic energy on various degrees of DS in both pulsatile and nonpulsatile flow with mock system. Using a pulsatile pump, pulsatility disappeared above 50% DS while hemodynamic energy was maintained. Therefore, our results suggest that pulsatile flow has a better effect than nonpulsatile flow in reserving hemodynamic energy after stenotic lesion.
More Related Videos
07:30In Vitro Model of Physiological and Pathological Blood Flow with Application to Investigations of Vascular Cell Remodeling
Published on: November 3, 2015
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Related Concept Videos
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Blood Flow
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...