Related Experiment Video
Updated: May 28, 2026

Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Interexaminer reliability of thoracic motion palpation using confidence ratings and continuous analysis
Robert Cooperstein1, Michael Haneline, Morgan Young
1Professor, Palmer Chiropractic College, San Jose, CA.
Objective:
Motion palpation is integral to most chiropractic techniques and can be found in curricula of most every chiropractic college. Paradoxically, most studies do not show strong reliability for motion palpation. The purpose of this study was to determine if allowing motion palpators to rate their confidence in their findings, as well using a continuous data analytic method, would influence the level of concordance.
Methods:
Subjects were 52 asymptomatic chiropractic student volunteers. Two palpators assessed posterior to anterior glide of T3-10 in the prone position, alternating in their order and blinded as to each other's results. Each examiner identified the location of maximal restriction in this range and also whether they were "very confident" or "not confident" in their finding.
Results:
For all subjects combined, the examiners' calls were "poor": intraclass correlation coefficient [2,1] = .3110 (95% CI, .0458-.5358). In contrast, interexaminer agreement was "good" when both examiners were very confident: intraclass correlation coefficient [2,1] = .8266 (95% CI, 0.6257-0.9253).
Conclusion:
When each examiner was "very confident" as to the most fixated thoracic segment, the levels they identified were very close. This corresponds to "good" agreement, an uncommon result in most interexaminer motion palpation studies. Thus, the confidence level of examiners had an effect on the interexaminer reliability of thoracic spine. Our novel continuous measures, statistical methodology, and subtyping the subjects according to the confidence of the palpators seem more capable than level-by-level discrete analysis of detecting interexaminer agreement.
Related Concept Videos
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Assessment of the Abdomen III: Palpation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
