Related Experiment Video
Updated: May 28, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Preparation and evaluation of hydrophilic C18 monolithic sorbents for enhanced polar compound retention in liquid
Yun Li1, Xin Xie, Milton L Lee
1Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, Liaoning, China.
Abstract:
Hydrophilic C18 monolithic polymer sorbents were synthesized for use in solid phase extraction (SPE) and in capillary liquid chromatography (LC). The approach involved incorporating both hydrophobic and hydrophilic monomers into a monolithic material, by copolymerization of stearyl methacrylate (SMA), poly(ethylene glycol) methyl ether methacrylate (PEGMEMA) and ethylene dimethacrylate (EDMA) in the presence of selected porogens, to produce translucent mesoporous monolithic materials in bulk (SPE) or white macroporous monoliths inside fused silica capillary columns (capillary LC). A capillary column containing one of the hydrophilic C18 monoliths (i.e. poly(SMA-co-PEGMEMA-co-EDMA) with 15% (w/w) PEGMEMA) demonstrated nearly 35% reduction in retention of polycyclic aromatic compounds and greater than 40% increase in retention of phenols compared to a hydrophobic C18 monolithic column. In addition, the hydrophilic monolith demonstrated significantly improved resolution of phenols. Similar monolithic materials prepared in bulk were ground and sieved to obtain 45-65 μm particles with desired rigidity for SPE. To achieve optimum extraction performance for phenols, several parameters, including sample pH and volume, and eluent type and volume, were investigated. Under optimized experimental conditions, the method demonstrated good sensitivity (1.6 ng/mL LOD) and linearity (R(2)>0.97 for 10-200 ng/mL). Again, incorporation of 15% (w/w) PEGMEMA in the monolith increased the extraction efficiency of phenols in water from approximately 20% to 67-92% compared to a hydrophobic C18 monolithic material. Increased wettability of the sorbent by the aqueous sample matrix and the presence of hydrogen-bonding interactions are responsible for the improved retention of polar compounds.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Analyte Adsorption and Distribution
Ion Exchange
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Elution Process
