Abstract:
Prior studies have found a 3%-6% clinically significant error rate in radiology practice. We set out to assess discrepancy rates between subspecialty-trained university-based neuroradiologists. Over 17 months, university neuroradiologists randomly reviewed 1000 studies and reports of previously read examinations of patients in whom follow-up studies were read. The discrepancies between the original and "second opinion" reports were scored according to a 5-point scale: 1, no change; 2, clinically insignificant detection discrepancy; 3, clinically insignificant interpretation discrepancy; 4, clinically significant detection discrepancy; and 5, clinically significant interpretation discrepancy. Of the 1000 studies, 876 (87.6%) showed agreements with the original report. The neuroradiology division had a 2.0% (20/1000; 95% CI, 1.1%-2.9%) rate of clinically significant discrepancies involving 8 CTs and 12 MR images. Discrepancies were classified as vascular (n = 7), neoplastic (n = 9), congenital (n = 2), and artifacts (n = 2). Individual neuroradiologist's scores ranged from 0% to 7.7% ± 2.3% (n = 18). Both CT and MR imaging studies had a discrepancy rate of 2.0%. Our quality assessment study could serve as initial data before intervention as part of a PQI project.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...