Related Experiment Video
Updated: May 28, 2026

Laparoscopic Non-Mesh Cerclage Pectopexy with Uterine Preservation for Pelvic Organ Prolapse
Published on: October 25, 2024
Management of the malpositioned levonorgestrel-releasing intrauterine system
1Maccabi Health Care Services, 68125 Tel-Aviv, Israel.
Background:
The management of a malpositioned levonorgestrel (LNG)-releasing intrauterine system (IUS) can present a clinical challenge, complicated by the high cost of replacing it with a new device. We tried to challenge the guidelines and common practice that usually suggest prompt removal of any malpositioned IUS and replacement with a new one.
Study Design:
We present our experience with 18 patients in whom the LNG-releasing IUS was found during a routine sonographic evaluation to be displaced towards the cervical canal 2 to 36 months postinsertion. Using an alligator forceps, the device was repositioned in the uterine cavity.
Results:
The procedure was deemed successful in 17 (94.4%) of 18 cases. In 3 (17.6%) of the 17 successful procedures, the LNG-releasing IUS was found again to be malpositioned within 2 months. No complications were noted, and no postprocedural infection occurred.
Conclusion:
Repositioning of a malpositioned LNG-releasing IUS should be considered, as it is an easy and simple manipulation that can be done in the office with a high success rate and minimal risk of complications.
Related Concept Videos
Intrauterine Drug Delivery Systems
Birth Control Methods
Mitral Valve Prolapse III: Nursing Management
Oral Drug Delivery Systems: Continuous-Release Systems
Modified-Release Drug Delivery Systems: Rate-Programmed I