Correction formula for creatinine concentration with glucose in dialysate
Charoen Kaitwatcharachai1, Somthawil Kaitwatcharachai, Dullached Wiriyasombat
1Division of Medicine, Hat Yai Hospital, Songkhla, Thailand. kcharoen007@hotmail.com
High glucose in peritoneal dialysis (PD) fluid interferes with creatinine tests. Correcting creatinine levels using dialysate glucose and creatinine ratios is crucial for accurate PD treatment and membrane transport assessment.
Area of Science:
- Nephrology
- Clinical Chemistry
- Biomedical Engineering
Background:
- High glucose concentrations in peritoneal dialysis (PD) fluid can interfere with creatinine measurements.
- This interference may lead to inaccuracies in assessing PD treatment effectiveness and patient outcomes.
- Accurate creatinine measurement is essential for clinical decision-making in PD.
Purpose of the Study:
- To evaluate the impact of glucose on creatinine measurements in PD dialysate.
- To compare different methods for correcting creatinine levels in the presence of glucose.
- To determine the most suitable method for clinical practice in PD.
Main Methods:
- Creatinine powder in 0.1 N HCl served as the standard reference.
- Creatinine measurements were performed on unused dialysate solutions with varying glucose concentrations.
- Twardowski's and Tam's formulas were used for creatinine correction.
- Membrane transport characteristics were determined using established criteria for comparison.
Main Results:
- Mean creatinine concentrations varied significantly between the standard method and the two correction formulas.
- Twardowski's formula yielded the lowest mean creatinine concentration.
- High correlation coefficients (r=0.80-0.98) were observed between glucose and creatinine interference with direct measurement and Twardowski's formula.
- Classification of membrane transport characteristics differed based on the correction formula used.
Conclusions:
- Creatinine correction in PD dialysate is critical for accurate results.
- Correction using the ratio of fresh dialysate creatinine and glucose may be clinically practical.
- Accurate creatinine measurements are vital for effective PD management.
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Serum Studies: Renal Function Tests
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...