Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The Multifaceted Nature of Tuberous Sclerosis Complex.

Sultan Qaboos University medical journal·2025
Same author

Path-dependent morphology of CH<sub>4</sub> hydrates and their dissociation studied with high-pressure microfluidics.

Lab on a chip·2024
Same author

Transfer Learning of Full Molecular Weight Distributions via High-Throughput Computer-Controlled Polymerization.

Journal of chemical information and modeling·2023
Same author

Templated Reactive Crystallization of Active Pharmaceutical Ingredient in Hydrogel Microparticles Enabling Robust Drug Product Processing.

Journal of pharmaceutical sciences·2023
Same author

Microfluidic Particle Engineering of Hydrophobic Drug with Eudragit E100─Bridging the Amorphous and Crystalline Gap.

Molecular pharmaceutics·2022
Same author

Correction to: Control of Drug-Excipient Particle Attributes with Droplet Microfluidic-based Extractive Solidification Enables Improved Powder Rheology.

Pharmaceutical research·2022

Related Experiment Video

Updated: May 27, 2026

Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique
10:12

Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique

Published on: June 12, 2015

Filtering microfluidic bubble trains at a symmetric junction.

Pravien Parthiban1, Saif A Khan

  • 1Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, E5-02-28, Singapore 117576.

Lab on a Chip
|November 5, 2011
PubMed
Summary
This summary is machine-generated.

A symmetric microfluidic junction unexpectedly sorts bubbles into one arm. This bubble sorting is achieved by controlling bubble train speed and analyzing hydrodynamic resistance, enabling precise microfluidic control.

More Related Videos

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow
09:45

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow

Published on: February 4, 2011

A Microfluidic System with Surface Patterning for Investigating Cavitation Bubble(s)&#8211;Cell Interaction and the Resultant Bioeffects at the Single-cell Level
11:14

A Microfluidic System with Surface Patterning for Investigating Cavitation Bubble(s)–Cell Interaction and the Resultant Bioeffects at the Single-cell Level

Published on: January 10, 2017

Related Experiment Videos

Last Updated: May 27, 2026

Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique
10:12

Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique

Published on: June 12, 2015

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow
09:45

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow

Published on: February 4, 2011

A Microfluidic System with Surface Patterning for Investigating Cavitation Bubble(s)&#8211;Cell Interaction and the Resultant Bioeffects at the Single-cell Level
11:14

A Microfluidic System with Surface Patterning for Investigating Cavitation Bubble(s)–Cell Interaction and the Resultant Bioeffects at the Single-cell Level

Published on: January 10, 2017

Area of Science:

  • Fluid dynamics
  • Microfluidics
  • Non-equilibrium physics

Background:

  • Microfluidic devices are widely used for fluid manipulation.
  • Bubble dynamics in microchannels can significantly alter flow resistance.
  • Symmetric junctions typically result in symmetric flow splitting.

Purpose of the Study:

  • To investigate the unexpected bubble sorting behavior in a nominally symmetric microfluidic junction.
  • To understand the underlying mechanisms of bubble-induced flow asymmetry.
  • To derive criteria for predicting bubble filtering in microfluidic systems.

Main Methods:

  • Quantifying bubble-induced hydrodynamic resistance modulation in microchannels.
  • Analyzing bubble train dynamics, including speed and spatial periodicity.
  • Investigating flow behavior in symmetric microfluidic geometries under varying bubble concentrations.

Main Results:

  • Demonstrated exclusive sorting of bubbles into one arm of a symmetric microfluidic junction.
  • Identified bubble train speed and spatial periodicity as key factors for filtering.
  • Discovered conditions where microchannel flow resistance decreases with increased bubble presence.

Conclusions:

  • A nominally symmetric microfluidic junction can exhibit asymmetric bubble sorting behavior.
  • Bubble train dynamics and hydrodynamic resistance modulation are crucial for achieving this filtering effect.
  • An exact criterion was derived to predict asymmetric bubble traffic in symmetric microfluidic geometries.