Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Near-infrared hollow waveguide gas sensors
Corinna M Frey1, Florian Luxenburger, Stefan Droege
1University of Ulm, Institute of Analytical and Bioanalytical Chemistry, Ulm, Germany.
Abstract:
The development of a hollow core waveguide (HWG) gas sensor in combination with a fast and compact near-infrared (NIR) spectrometer is presented. The spectrometer operates in the spectral range of 1200-1400 nm and may thus be applied for the detection of gas-phase analytes providing NIR absorptions in that spectral window such as, e.g., methane. Since mid-infrared spectroscopy in combination with HWGs has already been successfully demonstrated for probing hydrocarbons in the gas phase, the present study investigates the achievable sensitivity in the NIR spectral regime. Methane has been selected as an exemplary analyte due to the fact that it shows strong absorption features in the mid-infrared (mid-IR) fingerprint area, but also overtone bands in the NIR. Since the HWG simultaneously serves as a miniaturized absorption gas cell and as an optical waveguide for NIR radiation, a compact yet optical and cost-efficient sensor device was established providing an interesting alternative in target sensing for mid-IR devices. The achieved limit of detection (LOD) was 5.7% (vol./vol.) methane for a 9.5 cm long HWG, 1.6% (vol./vol.) methane for a 39.1 cm long HWG, and 1.3% (vol./vol.) methane for a setup using a 77.4 cm long HWG, which provides the most practical HWG dimensions among the three investigated setups. Limit of quantitation (LOQ) values were calculated at 20.1% (vol./vol.) methane, 8.7% (vol./vol.) methane, and 5.6% (vol./vol.) methane, respectively.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Spectrometers