Related Experiment Video
Updated: May 27, 2026

Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Trace level analysis of corky off-flavor compounds: development of a new analytical method based on solid phase
Hans-Georg Schmarr1, Stefan Koschinski, Wei Sang
1Dienstleistungszentrum Ländlicher Raum Rheinpfalz, Competence Centre for Wine Research, Breitenweg 71, D-67435 Neustadt an der Weinstraße, Germany. hans-georg.schmarr@dlr.rlp.de
Abstract:
This work describes the development of a trace level (<1 ngL(-1)) analysis of haloanisoles in complex wine matrix. The suggested method involves sample preparation based on solid phase extraction, a clean-up to remove acidic compounds, concentration of the haloanisole fraction and large volume on-column injection into a multidimensional GC-MS system. Mass spectrometric detection in the selected ion mode allowed reliable quantification of 2,4,6-trichloroanisole (TCA) or 2,4,6-tribromoanisole (TBA), via their highly deuterated ([(2)H5]) isotopologues as internal standards (stable isotope dilution analysis; SIDA), which had prior been synthesized in house. The development of this new method had become necessary, as a one-dimensional HS-SPME-GC-ECD method, routinely applied for analysis of TCA in cork soaks, had to be extended for TeCA and TBA determination, but failed due to co-elutions within wine matrices. The newly developed SPE//MDGC-MS method provided detection limits well below olfactory thresholds of the analytes with 0.05 ngL(-1) (LOD), 0.19 ngL(-1) (LOQ) for TCA, 0.06 ngL(-1) (LOD), 0.21 ngL(-1) (LOQ) for TeCA, and 0.09 ngL(-1) (LOD), 0.34 ngL(-1) (LOQ) for TBA.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Qualitative Analysis
There are two main approaches to qualitative analysis:...