Related Experiment Video
Updated: May 27, 2026

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Biological and analytical variation of the human sweating response: implications for study design and analysis
Robert W Kenefick1, Samuel N Cheuvront, Leonard D Elliott
1US Army Research Institute of Environmental Medicine, Thermal and Mountain Medicine Division, Kansas St. Natick, MA 01760, USA. robert.kenefick@us.army.mil
Abstract:
Appropriate quantification of analytical and biological variation of thermoregulatory sweating has important practical utility for research design and statistical analysis. We sought to examine contributors to variability in local forearm sweating rate (SR) and sweating onset (SO) and to evaluate the potential for using bilateral measurements. Two women and eight men (26 ± 9 yr; 79 ± 12 kg) completed 5 days of heat acclimation and walked (1.8 l/min VO(2)) on three occasions for 30 min in 40°C, 20% RH, while local SR and SO were measured. Local SR measures among days were not different (2.14 ± 0.72 vs. 2.02 ± 0.79 vs. 2.31 ± 0.72 mg·cm(2)·min(-1), P = 0.19) nor was SO (10.47 ± 2.54 vs. 10.04 ± 2.97 vs. 9.87 ± 3.44 min P = 0.82). Bilateral SR (2.14 ± 0.72 vs. 2.16 ± 0.71 mg·cm(2)·min(-1), P = 0.56) and SO (10.47 ± 2.54 vs. 10.83 ± 2.48 min, P = 0.09) were similar and differences were ≤ 1 SD of day-to-day differences for a single forearm. Analytical imprecision (CV(a)), within (CV(i))-, and between (CV(g))-subjects' coefficient of variation for local SR were 2.4%, 22.3%, and 56.4%, respectively, and were 0%, 9.6%, and 41%, respectively, for SO. We conclude: 1) technologically, sweat capsules contribute negligibly to sweat measurement variation; 2) bilateral measures of SR and SO appear interchangeable; 3) when studying potential factors affecting sweating, changes in SO afford a more favorable signal-to-noise ratio vs. changes in SR. These findings provide a quantitative basis for study design and optimization of power/sample size analysis in the evaluation of thermoregulatory sweating.
More Related Videos
07:32Use of Galvanic Skin Responses, Salivary Biomarkers, and Self-reports to Assess Undergraduate Student Performance During a Laboratory Exam Activity
Published on: February 10, 2016
08:33A Cross-Disciplinary and Multi-Modal Experimental Design for Studying Near-Real-Time Authentic Examination Experiences
Published on: September 4, 2019
Related Concept Videos
Requirements for Human Life
Oxygen
Atmospheric air is only about 20 percent oxygen, but that oxygen is a key component of the chemical reactions that keep the body alive, including the reactions that produce ATP. Brain cells are susceptible to a lack of oxygen because they require a...
Body Temperature
Accessory Structures of the Skin: Sweat Glands
Sweat glands are classified as merocrine glands; that is, the secretions are excreted by exocytosis through a duct without affecting the cells of the gland. There...
Bioequivalence Experimental Study Designs: Repeated Measures, Cross-Over, Carry-Over, and Latin Square Designs