Related Experiment Video
Updated: May 27, 2026

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
Tracheal intubation through the I-gel™ supraglottic airway versus the LMA Fastrach™: a randomized controlled trial
Antoine Elie Halwagi1, Nathalie Massicotte, Alexandre Lallo
1Department of Anesthesiology, Centre Hospitalier de l'Université de Montréal, Hôpital Notre-Dame, Quebec, Canada.
Background:
The i-gel™ is a supraglottic airway device not requiring inflation of a cuff for lung ventilation. Its design allows for unobstructed passage of a tracheal tube and previous studies have demonstrated a favorable alignment with the glottic inlet. In this prospective randomized study, we compared the success rate of blind tracheal intubation using the i-gel and the laryngeal mask airway (LMA) Fastrach™.
Methods:
One hundred sixty patients requiring general anesthesia and airway management were randomized to tracheal intubation using the i-gel or the LMA Fastrach. After induction of general anesthesia, the allocated device was inserted and adequate lung ventilation was confirmed. Blind tracheal intubation was then attempted. First attempt and overall tracheal intubation success rates were evaluated and tracheal intubation times were measured.
Results:
Eighty patients were recruited in each study group. Successful tracheal intubation was obtained on the first attempt in 69% of patients with the i-gel and 74% of patients with the LMA Fastrach (95% confidence interval [CI] of difference, -9% to 19%, P = 0.60). The overall intubation success rate was lower using the i-gel than it was using the LMA Fastrach (73% vs 91%, 95% CI of difference, 7% to 31%, P < 0.0001).
Conclusions:
On first attempts, successful blind tracheal intubation was obtained at comparable rates using the i-gel and the LMA Fastrach. However, when the first attempt was unsuccessful, subsequent attempts through the i-gel did not significantly increase tracheal intubation success rate. The LMA Fastrach yielded a higher overall intubation success rate.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...