Computerized insulin infusion programs are safe and effective in the burn intensive care unit
Jeanne Lee1, Dale Fortlage, Kevin Box
1Division of Trauma, Surgical Critical Care and Burns, Department of Surgery, University of California San Diego, CA 92103, USA.
A new computer-guided insulin protocol safely controlled blood glucose in burn patients, significantly reducing severe hypoglycemia compared to traditional methods. This approach offers effective and reliable glucose management in intensive care settings.
Area of Science:
- Intensive Care Medicine
- Metabolic Control
- Burn Patient Management
Background:
- Effective glucose control is crucial for surgical intensive care unit (ICU) patient outcomes.
- Intensive insulin therapy shows promise in reducing complications, but traditional protocols risk severe hypoglycemia.
- Existing computer-guided glucose control programs report low hypoglycemia rates.
Purpose of the Study:
- To evaluate the efficacy and safety of an institutional computer-based intensive insulin protocol in burn patients.
- To determine if this protocol can be used effectively without increasing the risk of severe hypoglycemia.
Main Methods:
- A retrospective analysis of 31 burn ICU patients treated with a computer-based intravenous insulin protocol from January to December 2008.
- Blood glucose (BG) levels were monitored hourly, with adjustments made per the computer protocol for BG >200 mg/dl.
- Data on BG measurements, target range adherence, and hypoglycemic events were collected and analyzed.
Main Results:
- Out of 12,699 measurements, only 0.07% (eight measurements) were below 50 mg/dl, indicating a very low rate of severe hypoglycemia.
- Seventy-six percent of BG values fell within the target range of 90 to 150 mg/dl.
- Severe hyperglycemia (BG >300 mg/dl) occurred in only 0.2% of measurements, with no associated adverse events.
Conclusions:
- The adopted computer-based insulin protocol is highly effective for glucose control in burn patients.
- This protocol provides safe and reliable glycemic management, with significantly lower rates of severe hypoglycemia than traditional methods.
- The findings support the use of this institutional computer protocol for managing burn patients in the ICU.
More Related Videos
Related Concept Videos
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
Burn Injuries
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into rapid-acting...