Related Experiment Video
Updated: May 27, 2026

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
A feasibility study on gamma-ray tomography by Monte Carlo simulation for development of portable tomographic system
Jongbum Kim1, Sunghee Jung, Jinho Moon
1Korea Atomic Energy Research Institute, Dukjin-dong, Yuseong-gu, Daejon, The Republic of Korea. jong@kaeri.re.kr
Abstract:
The electron beam X-ray tomographic scanner has been used in industrial and medical field since it was developed two decades ago. However, X-ray electron beam tomography has remained as indoor equipment because of its bulky hardware of X-ray generation devices. By replacing X-ray devices of electron beam CT with a gamma-ray source, a tomographic system can be a portable device. This paper introduces analysis and simulation results on industrial gamma-ray tomographic system with scanning geometry similar to electron beam CT. The gamma-ray tomographic system is introduced through the geometrical layout and analysis on non-uniformly distributed problem. The proposed system adopts clamp-on type device to actualize portable industrial system. MCNPx is used to generate virtual experimental data. Pulse height spectra from F8 tally of MCNPx are obtained for single channel counting data of photo-peak and gross counting. Photo-peak and gross counting data are reconstructed for the cross-sectional image of simulation phantoms by ART, Total Variation algorithm and ML-EM. Image reconstruction results from Monte Carlo simulation show that the proposed tomographic system can provide the image solution for industrial objects. Those results provide the preliminary data for the tomographic scanner, which will be developed in future work.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...