Related Experiment Video
Updated: May 27, 2026

11:56
In Vitro Bioluminescence Assay to Characterize Circadian Rhythm in Mammary Epithelial Cells
Published on: September 28, 2017
PVI's inconvenient truths: lights out for dormant reconnection?
Journal of Cardiovascular Electrophysiology
|November 16, 2011
Summary
No abstract available in PubMed .
Related Concept Videos
Restarting Stalled Replication Forks
DNA replication is initiated at sites containing predefined DNA sequences known as origins of replication. DNA is unwound at these sites by the minichromosome maintenance (MCM) helicase and other factors such as Cdc45 and the associated GINS complex.The unwound single strands are protected by replication protein A (RPA) until DNA polymerase starts synthesizing DNA at the 5’ end of the strand in the same direction as the replication fork. To prevent the replication fork from falling apart, a...
Restarting Stalled Replication Forks
DNA replication is initiated at sites containing predefined DNA sequences known as origins of replication. DNA is unwound at these sites by the minichromosome maintenance (MCM) helicase and other factors such as Cdc45 and the associated GINS complex.The unwound single strands are protected by replication protein A (RPA) until DNA polymerase starts synthesizing DNA at the 5’ end of the strand in the same direction as the replication fork. To prevent the replication fork from falling apart, a...
Power System Three-Phase Short Circuits
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
Conservation of AC Power
The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
Three-Phase Short Circuit—Unloaded Synchronous Machine
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Resting Potential Decay
The resting membrane potential of a neuron (-70mV) is sustained due to the selective ion permeability of the membrane. At the resting potential, the membrane is slightly permeable to ions like sodium (Na+) and chloride (Cl−) and highly permeable to potassium ions (K+). Differences in the ions' concentration inside the cell compared to the outside are maintained by membrane transport proteins like channels and pumps.
At rest, the K+ is the main ion that moves across the membrane through...
At rest, the K+ is the main ion that moves across the membrane through...
