Related Experiment Video
Updated: May 27, 2026

Iris Fixation via External Pentagram Suturing
Published on: May 5, 2022
Black-on-clear piggyback technique for a black occlusive intraocular device in intractable diplopia
Stephen D Byard1, Richard M H Lee, Fook Chang Lam
1Sussex Eye Hospital, Brighton, United Kingdom.
Abstract:
Black occlusive intraocular devices have been used successfully for intractable binocular diplopia. We describe a novel technique of implanting both a black occlusive device and a clear poly(methyl methacrylate) intraocular lens (IOL) in the capsular bag during phacoemulsification surgery. If the need should arise at a later date, this approach will allow safer and easier explantation of the black occlusive device, avoiding the need for IOL exchange.