[Severe tricuspid regurgitation due to ventricular pacing lead - a case report]
Ireneusz Jedliński1, Maria Jamrozek-Jedlińska, Paweł Bugajski
1Pracownia Echokardiografii, NSZOZ Medicor, Poznań. irejed@wp.pl
Abstract:
We present a case of severe symptomatic tricuspid valve regurgitation due to shifting of the septal leaflet of the valve toward the interventricular septum by a permanent ventricular pacemaker lead, making coaptation of the tricuspid leflats in systole impossible.