Related Experiment Video
Updated: May 27, 2026

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Accuracy of estimating resting oxygen uptake and implications for hemodynamic assessment
Nikhil Narang1, M Odette Gore, Peter G Snell
1Department of Internal Medicine, Texas Health Presbyterian Hospital, University of Texas Southwestern Medical School, Dallas, USA.
None:
The Fick principle (cardiac output [Q(c)] = oxygen uptake [Vo(2)]/arteriovenous oxygen difference) can be used to calculate Q(c), with VO(2) frequently estimated by derived equations. To compare the accuracy of measured versus estimated VO(2), data were analyzed from 2 studies in which VO(2) at rest was measured using the Douglas bag technique. One study comprised adults with diabetes, and the other was an exercise study of healthy adults. VO(2) at rest was estimated as VO(2) (ml/min) = 125 ml/min/m(2) × body surface area (m(2)), with sensitivity analyses evaluating 2 other commonly used equations. Mean absolute difference (milliliters per minute) and ordinary least products regression were used to assess agreement between measured and estimated VO(2). Overall, mean measured versus estimated VO(2) differed significantly (307.2 ± 75.2 vs 259.9 ± 36.7 ml/min, p <0.0001), with a mean absolute difference of 52.9 ± 43.2 ml/min (p <0.0001); 20% of the estimates differed by >25% from the measured VO(2). Mean absolute difference increased from 36.7 ml/min in the lowest body mass index group (<25 kg/m(2)) to 91.7 ml/min in the highest group (≥40 kg/m(2)) (p for trend = 0.001) and was significantly higher in men than in women (65.6 vs 33.9 ml/min, p = 0.001); error was similar by median-split age (p = 0.65) and race (p = 0.34). Similar results were obtained when evaluating each of the other 2 estimating equations. Estimation of VO(2) at rest is inaccurate, especially in men and with increasing adiposity. In conclusion, when clinical hemodynamic assessment is performed, VO(2) should be measured, not estimated.
More Related Videos
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Factors Affecting Respiration
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.