Related Experiment Video
Updated: May 27, 2026

How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
Reference values of nocturnal oxygenation for use in outpatient oxygen weaning protocols in premature infants
Lawrence Rhein1, Tregony Simoneau, Jaclyn Davis
1Division of Respiratory Diseases, Children's Hospital Boston, 300 Longwood Avenue, Boston, MA 02467, USA. lawrence.rhein@childrens.harvard.edu
Objective:
To define reference ranges for oxygen saturation (SpO(2) ) values in healthy full-term infants in the first days of life and in preterm infants off supplemental oxygen as they approach neonatal intensive care unit (NICU) discharge.
Methods:
From April 2009 to March 2010, we enrolled convenience samples of full-term infants from the newborn nursery and former preterm infants who did not require supplemental oxygen at the time of discharge from the NICU. Overnight SpO(2) and signal quality recordings were obtained and analyzed for duration of artifact-free recording time (AFRT), time (s) with SpO(2) less than several different target saturations (90-95%), and number of falls in SpO(2) by ≥4% and ≥10%.
Results:
We studied 102 full-term infants and 52 preterm infants. Preterm and full-term infants spent similar amounts of time less than 90%, 91%, 92%, 93%, 94%, and 95% although preterm infants had more falls in SpO(2) by ≥4% per hour of AFRT. Over 67% of term and preterm infants spent less than 6% of their time below 93%.
Conclusion:
These data represent reference SpO(2) ranges for both preterm infants not requiring supplemental oxygen at NICU discharge and full-term infants in the first days of life. As we currently lack guidelines dictating the optimal target oxygen saturations for infants and the acceptable maximal time that they can safely spend below set target saturations, our data may serve as a guide to interpreting SpO(2) recordings of premature outpatient infants who are weaning from supplemental oxygen.
More Related Videos
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
05:45Delivery of In Vivo Acute Intermittent Hypoxia in Neonatal Rodents to Prime Subventricular Zone-derived Neural Progenitor Cell Cultures
Published on: November 2, 2015
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...