Related Experiment Video
Updated: May 27, 2026

Three-Dimensional Shape Modeling and Analysis of Brain Structures
Published on: November 14, 2019
Would gestational age and presence of brain anomalies affect interobserver reliability of fetal head biometry? Using
Mona S M Salman1, Hatem A Mousa, Peter Twining
1Fetal and Maternal Medicine Department, Nottingham University Hospitals NHS Trust, Nottingham, UK. moghazymona@yahoo.com
Abstract:
The objective was to assess interobserver reliability of fetal head biometry using archived three-dimensional (3-D) volumes and the impact of gestational age and presence of brain anomalies on examiners' performance. Seventy nine 3-D volume datasets of fetal head were examined: 27 were normal and 52 had brain abnormalities. Off-line analysis was done by three fetal medicine experts (E1, E2 and E2), all were blinded to history and patient details. Measurements of the biparietal diameter (BPD), head circumference (HC), lateral ventricle (Vp) and transcerebellar diameter (TCD) were compared between examiners and to two-dimensional (2-D) measurements. Comparisons were made at two gestational age groups (≤22 and >22 weeks) and in presence and absence of brain anomalies. The intraclass coefficient showed a significantly high level of measurement agreement between 3-D examiners and 2-D, with values >0.9 throughout (p < 0.001). Bias was evident between 3-D examiners. E2 produced smaller measurements. The mean percentage difference between this examiner and the other two in BPD, HC, Vp and TCD measurements was significant, of 1.6%, 1%, 4.9% and 1.8%, respectively. E1 measured statistically larger for HC and TCD. E3 measured significantly larger for only BPD. The presence of anomalies was of no influence on the 3-D examiners' performance except for E3 who showed bias in BPD measurements only in cases with brain anomalies. Unlike other examiners, bias of E2 was only seen at gestational age group ≤22 weeks. Limits of agreement in measurements between observers were narrow for all parameters but were widest for the Vp measurements, being ±23% of the mean difference. Despite the above bias, the actual mean difference between examiners was small and unlikely to be of any clinical significance. Off-line measurement of fetal head biometry using 3-D volumes is reliable. In our study, presence of brain anomalies was unlikely to influence the reproducibility of measurements. Gestational age seemed to be of an impact on examiners' bias. Among experts this bias may be of no clinical significance.
More Related Videos
08:03Midface Hypoplasia and Cranial Base Morphology in Syndromic Craniosynostosis: A Comparative Analysis Study Using a Predictive Regression Model
Published on: November 4, 2025
15:263D Modeling of the Lateral Ventricles and Histological Characterization of Periventricular Tissue in Humans and Mouse
Published on: May 19, 2015