Related Experiment Video
Updated: May 27, 2026

In Vitro Evaluation of The Effects Of Er,Cr:YSGG and Diode Lasers Used on Titanium Cylinder
Published on: June 6, 2025
Local tissue temperature increase of a generic implant compared to the basic restrictions defined in safety
Adamos Kyriakou1, Andreas Christ, Esra Neufeld
1Foundation for Research on Information Technologies in Society (IT'IS), Zürich, Switzerland. adamos@itis.ethz.ch
Abstract:
The objective of this study was to investigate if persons with implantable medical devices are intrinsically protected by the current electromagnetic safety guidelines. For inter-laboratory comparisons, the U.S. Food and Drug Administration has defined a generic implant as consisting of an insulated wire with noninsulated tips, simulating active implants composed of a metallic case, and insulated wires with electric contacts at the tip. In this study, we determined the amplitude of the uniform electric fields induced in body tissues that cause a local increase in the tissue temperature by 1 °C in the presence of this generic implant for a wide range of frequencies and wire lengths. The field amplitudes were compared to the basic restrictions of the current exposure guidelines for both occupational and uncontrolled exposure. Results showed that a 1 °C temperature increase in the tissues around the tips of the generic implant can be reached for field strengths much smaller than 1% of those in the basic restrictions. The simulated results were validated by experimental evaluations. The impact of perfusion was investigated and was found to lead to a reduction in the local temperature peak by only 1.6-3 times. Additional simulations inside an inhomogeneous anatomical model were performed to ascertain whether similar heating as in the generic model was observed. The significant temperature elevations due to the presence of a generic implant indicate that demonstrating compliance with the basic restrictions might not be sufficient for persons with implants. Special considerations may be required, especially in the case of novel, emerging technologies that feature strong near-fields at frequencies below 10 MHz (e.g., wireless power-transfer systems).
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Factors Affecting Body Temperature
Factors may include:
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
