Ulnar variance: correlation of plain radiographs, computed tomography, and magnetic resonance imaging with anatomic
Daniel K Laino1, Catherine N Petchprapa, Steve K Lee
1Department of Orthopedic Surgery, NYU Hospital for Joint Diseases, New York, NY, USA. dklaino@gmail.com
Purpose:
Several techniques used to measure ulnar variance on a posteroanterior wrist radiograph have been described. It remains unclear whether they accurately represent the true ulnar variance of the patient. The purpose of this study was to correlate ulnar variance measurements on plain radiographs, computed tomography (CT), magnetic resonance imaging (MRI), and anatomic dissection.
Methods:
Posteroanterior (PA) radiographs, coronal and sagittal CT scans, and coronal MRI scans were obtained on 8 fresh-frozen cadaver wrists. The ulnar variance was measured by 5 reviewers. The specimens were then dissected, exposing the wrist joint. The ulnar variance was measured directly on each specimen using digital calipers. The inter-rater reliability was calculated for each imaging modality. The bias for each imaging modality was calculated using the digital caliper measurements as the true ulnar variance.
Results:
Intraclass correlation coefficients demonstrated excellent inter-rater reliability for each imaging modality. The average bias from the true variance was the following: PA radiograph, 0.77 mm; coronal CT, 0.96 mm; sagittal CT, 0.96 mm; MRI with articular cartilage, 0.73 mm; MRI excluding cartilage, 0.49 mm. The variance measured on all imaging modalities tended to underestimate the magnitude of the true variance.
Conclusions:
Ulnar variance measured on coronal MRI best reflected the true ulnar variance as measured directly using calipers. The CT scans demonstrated the greatest deviation from the true variance. However, differences were small and might not be clinically meaningful. All imaging modalities demonstrated excellent inter-rater reliability, with MRI being highest. All imaging modalities tended to underestimate the magnitude of the true variance.
Clinical Relevance:
The imaged underestimation of true ulnar variance should be taken into account when performing surgical procedures that alter the relative lengths of the radius and ulna.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging
Bones of the Upper Limb: Ulna