Organ volume by computed tomography correlates with longitudinal axis on ultrasound in patients with Gaucher disease
Deborah Elstein1, Maayan Tiomkin, Irith Hadas-Halpern
1Shaare Zedek Medical Center, Jerusalem, Israel. elstein@szmc.org.il
Objectives:
Although ultrasonography (US) may be recommended for repeat assessments of spleen and liver volumes, it is less readily used than magnetic resonance imaging and computed tomography (CT) because of concerns of accuracy and reproducibility. In monitoring spleen and liver volumes for Gaucher disease where volume changes underlie management decisions, in experienced hands, US has a place because some patients are evaluated for decades and sometimes several times annually. The purpose of this survey was to ascertain whether one can maximize the efficiency of US imaging by use of one US axis if it correlates with CT-generated volumes.
Methods:
A patient cohort from a large tertiary clinic dedicated to Gaucher disease was used. Thirty-seven patients with simultaneous abdominal CT and US evaluations (1992-2009), 27 (73%) at the advent of Gaucher-specific therapy, and followed both by CT and US up to 3 additional times (interval, ≥12 months) were included. Ultrasound evaluation of 3 axes, longitudinal, width, and depth, was performed by one radiologist; all organs including idiosyncratically shaped and massively enlarged organs were included.
Results:
There was a significant correlation between CT volume and US length axis for both spleen (0.619) and for liver (0.557) volumes (P = 0.01; 2-tailed for each).
Conclusion:
With some training, the use of the longitudinal axis by US assessment may suffice to approximate estimation of changes in organ volumes.
More Related Videos
08:39Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects
Published on: June 24, 2025
10:25A Dorsal Skinfold Window Chamber Tumor Mouse Model for Combined Intravital Microscopy and Magnetic Resonance Imaging in Translational Cancer Research
Published on: April 12, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies II: Ultrasonography
Imaging Studies for Cardiovascular System V: CT
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT