Concordance, variance, and outliers in 4 contemporary cardiac troponin assays: implications for harmonization
Jacobus P J Ungerer1, Louise Marquart, Peter K O'Rourke
1Department of Chemical Pathology, Pathology Queensland, Brisbane, Queensland, Australia. ungerer@mweb.co.za
Background:
Data to standardize and harmonize the differences between cardiac troponin assays are needed to support their universal status in diagnosis of myocardial infarction. We characterized the variation between methods, the comparability of the 99th-percentile cutoff thresholds, and the occurrence of outliers in 4 cardiac troponin assays.
Methods:
Cardiac troponin was measured in duplicate in 2358 patient samples on 4 platforms: Abbott Architect i2000SR, Beckman Coulter Access2, Roche Cobas e601, and Siemens ADVIA Centaur XP.
Results:
The observed total variances between the 3 cardiac troponin I (cTnI) methods and between the cTnI and cardiac troponin T (cTnT) methods were larger than expected from the analytical imprecision (3.0%-3.7%). The between-method variations of 26% between cTnI assays and 127% between cTnI and cTnT assays were the dominant contributors to total variances. The misclassification of results according to the 99th percentile was 3%-4% between cTnI assays and 15%-17% between cTnI and cTnT. The Roche cTnT assay identified 49% more samples as positive than the Abbott cTnI. Outliers between methods were detected in 1 patient (0.06%) with Abbott, 8 (0.45%) with Beckman Coulter, 10 (0.56%) with Roche, and 3 (0.17%) with Siemens.
Conclusions:
The universal definition of myocardial infarction should not depend on the choice of analyte or analyzer, and the between- and within-method differences described here need to be considered in the application of cardiac troponin in this respect. The variation between methods that cannot be explained by analytical imprecision and the discordant classification of results according to the respective 99th percentiles should be addressed.
More Related Videos
10:01Improvement of a Closed Chest Porcine Myocardial Infarction Model by Standardization of Tissue and Blood Sampling Procedures
Published on: March 12, 2018
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...
Acute Coronary Syndrome III: Diagnostic Studies
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...