Related Experiment Video
Updated: May 27, 2026

Wideband Optical Detector of Ultrasound for Medical Imaging Applications
Published on: May 11, 2014
Beam distortion detection and deflectometry measurements of gigahertz surface acoustic waves
Julien Higuet1, Tony Valier-Brasier, Thomas Dehoux
1Département d'Acoustique Physique, Université de Bordeaux, CNRS, UMR 5295, I2M, Talence F-33405, France.
Abstract:
Gigahertz acoustic waves propagating on the surface of a metal halfspace are detected using different all-optical detection schemes, namely, deflectometry and beam distortion detection techniques. Both techniques are implemented by slightly modifying a conventional reflectometric setup. They are then based on the measurement of the reflectivity change but unlike reflectometric measurements, they give access to the sample surface displacement. A semi-analytical model, taking into account optical, thermal, and mechanical processes responsible for acoustic waves generation, allows analyzing the physical content of the detected waveforms.