Are radiologists' goals for mammography accuracy consistent with published recommendations?
Sara L Jackson1, Andrea J Cook, Diana L Miglioretti
1Department of Internal Medicine, University of Washington, Seattle, WA 98104, USA. sljack@uw.edu
Rationale And Objectives:
Mammography quality assurance programs have been in place for more than a decade. We studied radiologists' self-reported performance goals for accuracy in screening mammography and compared them to published recommendations.
Materials And Methods:
A mailed survey of radiologists at mammography registries in seven states within the Breast Cancer Surveillance Consortium (BCSC) assessed radiologists' performance goals for interpreting screening mammograms. Self-reported goals were compared to published American College of Radiology (ACR) recommended desirable ranges for recall rate, false-positive rate, positive predictive value of biopsy recommendation (PPV2), and cancer detection rate. Radiologists' goals for interpretive accuracy within desirable range were evaluated for associations with their demographic characteristics, clinical experience, and receipt of audit reports.
Results:
The survey response rate was 71% (257 of 364 radiologists). The percentage of radiologists reporting goals within desirable ranges was 79% for recall rate, 22% for false-positive rate, 39% for PPV2, and 61% for cancer detection rate. The range of reported goals was 0%-100% for false-positive rate and PPV2. Primary academic affiliation, receiving more hours of breast imaging continuing medical education, and receiving audit reports at least annually were associated with desirable PPV2 goals. Radiologists reporting desirable cancer detection rate goals were more likely to have interpreted mammograms for 10 or more years, and >1000 mammograms per year.
Conclusion:
Many radiologists report goals for their accuracy when interpreting screening mammograms that fall outside of published desirable benchmarks, particularly for false-positive rate and PPV2, indicating an opportunity for education.
More Related Videos
13:44Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...