Rapid Point-of-Care Assay of Enoxaparin Anticoagulant Efficacy in Whole Blood
Published on: October 12, 2012
[Quality control of ISI/INR system in oral anticoagulant therapy]
1First Department of Medicine, Teikyo University School of Medicine.
Ten controlled plasmas and 4 thromboplastin reagents were distributed to 75 laboratories for measurement of prothrombin time (PT). The results were converted to prothrombin activity (PA). prothrombin ratio (PR) and international normalized ratio (INR). Among the 4 different ways of expression, the discrepancy between the results obtained by the different reagents was the smallest when the results were expressed by INR. However, the discrepancy of the results was still remained because of the different assay methods used routinely at these laboratories, even with the use of ISI/NR system (Instrumentation effects). In this study, reference curve of prothrombin time: INR was created using INR reference plasmas, which were selected from commercial control plasma using a standard thromboplastin reagent. INR's of 108 patients' plasmas were calculated by ISI/INR system on one hand, and by the use of the reference curve of the prothrombin: INR on the other hand. It was found that the discrepancy of the results obtained by different assay methods was significantly improved by the latter method, compared to those obtained by the conventional ISI/INR system.
Ten controlled plasmas and 4 thromboplastin reagents were distributed to 75 laboratories for measurement of prothrombin time (PT). The results were converted to prothrombin activity (PA). prothrombin ratio (PR) and international normalized ratio (INR). Among the 4 different ways of expression, the discrepancy between the results obtained by the different reagents was the smallest when the results were expressed by INR. However, the discrepancy of the results was still remained because of the different assay methods used routinely at these laboratories, even with the use of ISI/NR system (Instrumentation effects). In this study, reference curve of prothrombin time: INR was created using INR reference plasmas, which were selected from commercial control plasma using a standard thromboplastin reagent. INR's of 108 patients' plasmas were calculated by ISI/INR system on one hand, and by the use of the reference curve of the prothrombin: INR on the other hand. It was found that the discrepancy of the results obtained by different assay methods was significantly improved by the latter method, compared to those obtained by the conventional ISI/INR system.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
In Vitro Drug Release Testing: Overview, Development and Validation
Drug Product Performance: In Vitro–In Vivo Correlation
Endocarditis IV: Nursing Management
Venous Thrombosis III: Interprofessional Care