Related Experiment Video
Updated: Oct 12, 2026

Training Rats to Voluntarily Dive Underwater: Investigations of the Mammalian Diving Response
Published on: November 12, 2014
[Fatigue and performance of divers during a simulated, non-saturated oxygen-helium dive to 180 meters]
1Japan Marine Science and Technology Center, Yokosuka.
Abstract:
A non-saturated mixed-gas dive to 180 meters depth was carried out at JAMSTEC, using diving simulator (hyperbaric chamber) facilities. Compression started at 10:00 h with helium and oxygen and was carried out at a rate of 12 m/min. Decompression started at 11:15 h using the Comex Helox 180 Diving Manual. Decompression to 1 ATA required 49.2 h. A survey of subjective symptoms, sleep feelings and ball-bearing tests were performed. All night electrophysiological recording of subjects' sleep was performed and polygraphic analysis of nocturnal sleep was done with visual scoring. The results were as follows: Arriving at 180 meters, the complaint rate was 39.2% and fatigue was greater. The type of fatigue that was based on the composition + ratio of symptoms was that of mental fatigue. During the decompression it was recovery. The performance in the ball-bearing test decreased about 20% at a depth of 180 meters because of tremors and disturbance of attention as well as other factors showing symptoms of high-pressure nervous syndrome. The sleep feelings were different in experienced persons and non-experienced persons. The non-experienced persons had markedly decreased REM stages and slept badly all night. Based on these results, fatigue and the performance of divers were discussed.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Hyperpnea and Hyperventilation
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-IV
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...