Related Experiment Video
Updated: May 26, 2026

Nine-Grid Area Division Method: A New Ideal Bone Puncture Region for Percutaneous Vertebroplasty in Lumbar Spine
Published on: August 9, 2024
Quantitative volumetry of cement leakage in viscosity-controlled vertebroplasty
Michaela Gstöttner1, Alexandra Angerer, Rafal Rosiek
1Department of Orthopaedic Surgery, Medical University Innsbruck, Innsbruck, Austria. michaela.gstoettner@gmx.com
Study Design:
This study was designed as a cohort study comparing a prospective sample to a historic control group.
Objective:
The aim of the actual trial was to compare the rate of cement leakage by quantitative volumetry comparing viscosity-controlled and non-viscosity-controlled vertebroplasty.
Summary Of Background Data:
Percutaneous vertebroplasty (PVP) is a widespread safe and effective technique in the treatment of osteoporotic compression fractures and vertebral metastatic lesions. However, cement leakage has been identified as a problem of this technique. The leakage rates are reported to range from 7% to 90%. The main influence factor for leakage has been demonstrated to be cement viscosity. Assessment of appropriate injection viscosity is highly subjective and observer dependent. Viscosity-controlled vertebroplasty (Vertecem system) has been developed to objectively measure cement viscosity before injection. It introduces a viscosimeter to measure the actual cement viscosity before injection into the vertebra, and therefore may prevent leakages resulting from low-viscosity cement injections. Despite more than 800 Pubmed citations on PVP, there is only 1 report on distinct measurement of cement leakage by semiquantitative volumetry.
Methods:
A total of 111 vertebrae in 68 patients, in which PVP was performed for osteoporotic fractures, were included. Thirty-seven patients (76 operated vertebrae) were assessed prospectively using the viscosity-controlled vertebroplasty. The results were compared with a retrospective group of 31 patients (35 operated vertebrae) undergoing PVP without using a viscosimeter.
Results:
: There were no significant differences between the 2 groups in the applied volume of cement per fractured vertebra (P=0.73). The frequency of cement leakage in viscosimete-assisted vertebroplasty was 42.1% and 58.3% in the historic group. Cement leakage into the basivertebral vein (type B), was detected in 6.6% with and in 11.1% without viscosimetry.
Conclusions:
The use of viscosity-controlled vertebroplasty led to a decrease in the leakage rate from 58.3% to 42.1%. Leakage into the basivertebral vein with the risk of compression of nerval structures was reduced to almost 50% when viscosimetry was performed. It revealed to be a helpful tool for more unexperienced surgeons to assess the appropriate viscosity for vertebroplasty.
Related Concept Videos
Total Voids in Concrete
Porosity in Cement Paste
The balance of water to cement in the mix is critical—it...
Vebe Test
To conduct the test, concrete is placed into the slump cone. The concrete is filled in layers and...
Urodynamic Studies: Uroflowmetry
Measurement of Air Content in Concrete
The pressure method,...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies

