A comparison of reconstruction and viewing parameters on image quality and accuracy of stress myocardial CT perfusion
Brian B Ghoshhajra1, Ian S Rogers, Pal Maurovich-Horvat
1Cardiac MR PET CT Program, Department of Radiology and Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA. bghoshhajra@partners.org
Background:
Myocardial stress computed tomography perfusion (CTP) has similar diagnostic accuracy for detecting perfusion defects (PDs) versus single-photon emission computed tomography (SPECT). However, the optimal diagnostic viewing and image processing parameters for CTP are unknown.
Objective:
We sought to compare the diagnostic accuracy of different image processing techniques, cardiac phases, slice thicknesses, and viewing parameters for detection of PDs.
Methods:
A stress and rest dual-source CTP protocol was performed with adenosine. Twelve subjects with severe stenosis proven by quantitative coronary angiography (QCA), with corresponding territorial defects at SPECT, were selected as well as 7 controls (subjects with similar clinical suspicion but negative QCA and SPECT). Short-axis stress images were processed with 3 techniques: minimum intensity projection (MinIP), maximum intensity projection, and average intensity multiplanar reconstruction (MPR), 3 thicknesses (1, 3, 8 mm), and 2 phases (systolic, mid-diastolic). The resulting images (n = 1026) were randomized and interpreted by independent readers.
Results:
Diastolic reconstructions (8-mm MPR) showed the highest sensitivity (81%) to detect true PDs. The highest accuracy was achieved with the 8-mm (61%) and 1-mm (61%) MPR diastolic images. The most sensitive and accurate systolic reconstructions were 3-mm MinIP images. These findings related to viewing in relatively narrow window width and window level settings.
Conclusion:
Viewing parameters for optimal accuracy in detection of perfusion defects on CTP differ for systolic and diastolic images.
More Related Videos
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...