Related Experiment Video
Updated: May 26, 2026

Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
Rapid, simple, and highly sensitive analysis of drugs in biological samples using thin-layer chromatography coupled
Kenji Kuwayama1, Kenji Tsujikawa, Hajime Miyaguchi
1National Research Institute of Police Science, 6-3-1, Kashiwanoha, Kashiwa, Chiba 277-0882, Japan. kuwayama@nrips.go.jp
Abstract:
Rapid and precise identification of toxic substances is necessary for urgent diagnosis and treatment of poisoning cases and for establishing the cause of death in postmortem examinations. However, identification of compounds in biological samples using gas chromatography and liquid chromatography coupled with mass spectrometry entails time-consuming and labor-intensive sample preparations. In this study, we examined a simple preparation and highly sensitive analysis of drugs in biological samples such as urine, plasma, and organs using thin-layer chromatography coupled with matrix-assisted laser desorption/ionization mass spectrometry (TLC/MALDI/MS). When the urine containing 3,4-methylenedioxymethamphetamine (MDMA) without sample dilution was spotted on a thin-layer chromatography (TLC) plate and was analyzed by TLC/MALDI/MS, the detection limit of the MDMA spot was 0.05 ng/spot. The value was the same as that in aqueous solution spotted on a stainless steel plate. All the 11 psychotropic compounds tested (MDMA, 4-hydroxy-3-methoxymethamphetamine, 3,4-methylenedioxyamphetamine, methamphetamine, p-hydroxymethamphetamine, amphetamine, ketamine, caffeine, chlorpromazine, triazolam, and morphine) on a TLC plate were detected at levels of 0.05-5 ng, and the type (layer thickness and fluorescence) of TLC plate did not affect detection sensitivity. In addition, when rat liver homogenate obtained after MDMA administration (10 mg/kg) was spotted on a TLC plate, MDMA and its main metabolites were identified using TLC/MALDI/MS, and the spots on a TLC plate were visualized by MALDI/imaging MS. The total analytical time from spotting of intact biological samples to the output of analytical results was within 30 min. TLC/MALDI/MS enabled rapid, simple, and highly sensitive analysis of drugs from intact biological samples and crude extracts. Accordingly, this method could be applied to rapid drug screening and precise identification of toxic substances in poisoning cases and postmortem examinations.
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
High-Performance Liquid Chromatography: Types of Detectors
MALDI-TOF Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...

