Cardiac output monitoring devices: an analytic review
Jahan Porhomayon1, Ali El-Solh, Peter Papadakos
1Department of Anesthesiology, VA Western New York Healthcare System, State University of New York at Buffalo School of Medicine and Biomedical Sciences, Buffalo, NY 14215, USA. jahanpor@buffalo.edu
Abstract:
To evaluate cardiac output (CO), both invasive and semi-invasive monitors are used in critical care medicine. The pulmonary artery catheter is an invasive tool to assess CO with the major criticism that the level of its invasiveness is not supported by an improvement in patients' outcomes. The interest in a lesser invasive techniques is high. Therefore, alternative techniques have been developed recently, and are used frequently in critical care medicine. Cardiac output can be monitored continuously by different devices that analyze the stroke volume and CO. The purpose of this review is to understand these new technologies and their applications and limitations.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...