Impact of a dedicated training program on the reproducibility of systolic dyssynchrony measures using tissue Doppler
Qing Zhang1, Yu-Jia Liang, Qian-Huan Zhang
1Li Ka Shing Institute of Health Sciences, Institute of Vascular Medicine and Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong.
Background:
The reproducibility of the measurement of mechanical dyssynchrony by echocardiography including Doppler tissue imaging has recently been questioned. The aim of this study was to ascertain the role of a dedicated training program to improve skills and the reproducibility of dyssynchrony assessment.
Methods:
In 70 patients with heart failure, color Doppler tissue images were acquired, and the time to peak systolic velocity of each segment and several dyssynchrony indices, including the standard deviation of time to peak systolic velocity, were measured by an expert to constitute a reference standard. The same images were then assessed by two beginners, who had only basic knowledge of dyssynchrony analysis after a 1-hour lecture, and two graduates, who had received a structured hands-on training program. Both sets of results were compared with the standard.
Results:
For the standard deviation of time to peak systolic velocity, the linear correlations between the standard and beginner 1 (r = 0.643) and beginner 2 (r = 0.532) were only modest (P < .001 for both). When referenced to the standard, interobserver variability was 18% for beginner 1 and 19% for beginner 2. Measurements with differences of ≥10 msec were found in 24% and 22% of cases by beginners 1 and 2, respectively. In contrast, the assessments made by graduates 1 and 2 were significantly improved. The correlation coefficients were 0.935 and 0.929 (P < .001 for both), and interobserver variability values were 8% and 7%. The prevalence rates of measurements with differences ≥ 10 msec were 1.5% and 3%, respectively.
Conclusions:
There is a learning curve for the measurement of systolic dyssynchrony using Doppler tissue imaging, but good reproducibility can be achieved by the use of a dedicated training program.
More Related Videos
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...