Related Experiment Video
Updated: May 26, 2026

Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
Trace element measurements in high purity synthetic Al2O3 via neutron activation
Stephen C McGuire1, Louis N Hand
1Ward Laboratory, Department of Physics, Cornell University, Ithaca, NY 14853, USA. smcguire1@cox.net
Abstract:
We present results from our use of thermal and fast neutron activation for the determination of trace elements in Al2O3 fabricated via the heat exchanger method (HEM™). This material has applications in microwave oscillators and gravity-wave detection. Typical concentrations obtained from these measurements show the presence of Cr (5 ppb+20%), Ti (300 ppb±9.7%), Mo (1500 ppb±15%) and Sc (3 ppb±6.7%). Details of the experiments and interpretations are given.
More Related Videos
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Lab