A semi-mechanistic gastric emptying pharmacokinetic model for (13)C-octanoic acid: an evaluation using simulation
Kayode Ogungbenro1, Leon Aarons
1Centre for Applied Pharmacokinetic Research, The University of Manchester, Oxford Road, Manchester M13 9PL, United Kingdom. kayode.ogungbenro@manchester.ac.uk
Abstract:
The aim of this paper is to assess the performance of a new mechanistic model for analysing (13)C-octanoic acid breath test data using simulation studies. The (13)C-octanoic acid breath test is widely used for indirect assessment of the rate of gastric emptying and it is yet to achieve universal acceptance due to inconsistencies when the results are compared with simultaneous and direct measurements using scintigraphy. The new semi-mechanistic model has five separate compartments; stomach, intestine, central and peripheral body and breath compartments. Stomach and breath profiles were simulated for 50 individuals under four conditions: variability on all parameters; no variability on the rate constant of gastric emptying and the rate constant of absorption; variability on the rate constant of gastric emptying and the rate constant of absorption only; and no variability on all parameters. A mono-exponential model was fitted to the stomach profile and the new semi-mechanistic model and three other widely used methods were fitted to the breath profiles. The gastric emptying half times from stomach profiles correlate better (R(2)=1,1,1,1 for the four conditions) with the half emptying times from the semi-mechanistic model compared with half emptying times from the modified exponential model (R(2)=0.72,0.53,0.88,1), Ghoos method (R(2)=0.72,0.54,0.88,1) and Wagner-Nelson method (R(2)=0.79,0.68,0.89,1) for the four simulation studies. The semi-mechanistic model is very effective for the assessment of GE using the (13)C-octanoic acid breath test and could be applied in the development of drugs that influence GE.
More Related Videos
13:17The Mesenteric Lymph Duct Cannulated Rat Model: Application to the Assessment of Intestinal Lymphatic Drug Transport
Published on: March 6, 2015
10:20In vitro Digestion of Emulsions in a Single Droplet via Multi Subphase Exchange of Simulated Gastrointestinal Fluids
Published on: November 18, 2022
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
One-Compartment Open Model for Extravascular Administration: Zero-Order Absorption Model
Zero-order absorption maintains a steady rate irrespective of the amount of drug left to be absorbed, making it a constant process. In the...
One-Compartment Open Model for Extravascular Administration: First-Order Absorption Model
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...