Using a blood pressure harmonic variability index to monitor the cerebral blood flow condition in stroke patients
Related Experiment Video
Updated: May 26, 2026

Functional Transcranial Doppler Ultrasound for Monitoring Cerebral Blood Flow
Published on: March 15, 2021
Chao-Tsung Chen1, Shih-Min Huang, Hsin Hsiu
1Department of Traditional Chinese Medicine, Taipei City Hospital RenAi Branch, Taipei, Taiwan, ROC.
Objective:
Beat-to-beat cardiovascular variability analysis provides important information on the autonomic control. Bilateral radial arterial blood pressure waveforms (BPW) in stroke patients were compared to explore the efficacy of frequency-domain variability index in evaluating bilateral differences in the cerebral blood-flow condition.
Methods:
Five-minute BPW signals were obtained in 22 stroke patients (Group S) and 21 healthy volunteers (control Group C). Amplitude proportions of the acquired pulses and their coefficient of variance (CVn) were calculated for 1st-10th harmonics to evaluate the blood pressure harmonic variability (BPHV).
Results:
In Group S, CV1-CV7 were significantly larger on the stroke side than on the contralateral side. CV1, CV3-CV5 and CV7 were significantly larger on the stroke side in Group S than on either side in Group C.
Conclusions:
We first demonstrate the feasibility of using BPHV index to noninvasively detect the bilateral difference in cerebral vascular resistance in stroke patients. Two main indexes could be developed based on the present results: (1) bilateral differences in BPHV in stroke patients; (2) BPHV differences between normal and stroke subjects. It might have meaning in developing an easy-to-perform, noninvasive and continuous monitoring technique to improve the early detection and disease progress monitoring for stroke.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: