An implantable RF solenoid for magnetic resonance microscopy and microspectroscopy

D S Rivera1, M S Cohen, W G Clark

  • 1Department of Neurophysics, Max Planck Institute,Leipzig, Germany. dsrivera@ieee.org

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
Magnetic Field of a Solenoid01:18

Magnetic Field of a Solenoid

A solenoid is a conducting wire coated with an insulating material, wound tightly in the form of a helical coil. The magnetic field due to a solenoid is the vector sum of the magnetic fields due to its individual turns. Therefore, for an ideal solenoid, the magnetic field within the solenoid is directly proportional to the number of turns per unit length and the current. Conversely, the magnetic field outside the solenoid is zero.
Consider a solenoid with 100 turns wrapped around a cylinder of...
NMR Spectrometers: Overview01:20

NMR Spectrometers: Overview

NMR spectrometers consist of a strong magnet, a radiofrequency transmitter, and a detector attached to a computer console for recording spectra of samples containing NMR-active nuclei. In first-generation NMR instruments called continuous-wave spectrometers, the resonance frequencies of the nuclei are determined by frequency-sweep or field-sweep methods. The magnetic field strength is fixed and the rf signal is swept in the former, while the radiofrequency signal is fixed and the magnetic field...
Solenoids01:17

Solenoids

A solenoid is a conducting wire coated with an insulating material, wound tightly in the form of a helical coil. The magnetic field for a solenoid is the vector sum of the magnetic field due to its individual turns. For an ideal solenoid, the magnetic field inside is almost uniform and parallel to the solenoid axis, while the magnetic field outside the solenoid is nearly zero.
Each turn in a solenoid can be approximated as a circular current carrying coil that generates a dipole moment. The...