Related Experiment Video
Updated: May 26, 2026

Evaluation of Host-Pathogen Responses and Vaccine Efficacy in Mice
Published on: February 22, 2019
Aerosolized vaccine as an unexpected source of false-positive Bordetella pertussis PCR results
Hossein Salimnia1, Paul R Lephart, Basim I Asmar
1Detroit Medical Center University Laboratories, Detroit, Michigan, USA.
Abstract:
When 13 of 13 nasal wash specimens from a single pediatrician's office tested positive for low quantities of Bordetella pertussis DNA, we suspected prelaboratory contamination. Investigation revealed that Pentacel and Adacel vaccines contain high copy numbers of B. pertussis DNA, which can be aerosolized, causing false-positive B. pertussis PCR results.
Insights
Vaccine contamination can cause false positive results in pertussis testing. Bordetella pertussis DNA in vaccines may aerosolize, leading to inaccurate PCR detection in nasal wash specimens.
Area of Science:
- Microbiology
- Vaccinology
- Molecular Diagnostics
Background:
- Pertussis (whooping cough) is a significant public health concern.
- Accurate diagnostic methods are crucial for disease surveillance and control.
- Potential sources of prelaboratory contamination in molecular testing require careful consideration.
Purpose of the Study:
- To investigate the cause of unexpected positive Bordetella pertussis PCR results in nasal wash specimens.
- To identify potential sources of prelaboratory contamination in a clinical setting.
Main Methods:
- Analysis of 13 nasal wash specimens from a single pediatrician's office.
- Investigation into potential contamination sources, including vaccine lots.
- Polymerase Chain Reaction (PCR) testing for Bordetella pertussis DNA.
Main Results:
- All 13 nasal wash specimens tested positive for low quantities of Bordetella pertussis DNA.
- Investigation identified Pentacel and Adacel vaccines as containing high copy numbers of B. pertussis DNA.
- Aerosolization of vaccine DNA was identified as the likely cause of false-positive PCR results.
Conclusions:
- Vaccine components can be a source of prelaboratory contamination in Bordetella pertussis PCR testing.
- Aerosolized DNA from certain vaccines can lead to false-positive diagnostic results.
- Careful handling and environmental controls are necessary to prevent vaccine-related contamination in molecular diagnostics.