Related Experiment Video
Updated: May 26, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Electronic nose breathprints are independent of acute changes in airway caliber in asthma
Zsofia Lazar1, Niki Fens, Jan van der Maten
1Department of Pulmonology, Semmelweis University, Diósárok u. 1/c, 1125 Budapest, Hungary. zsofia.lazar@yahoo.com
Abstract:
Molecular profiling of exhaled volatile organic compounds (VOC) by electronic nose technology provides breathprints that discriminate between patients with different inflammatory airway diseases, such as asthma and COPD. However, it is unknown whether this is determined by differences in airway caliber. We hypothesized that breathprints obtained by electronic nose are independent of acute changes in airway caliber in asthma. Ten patients with stable asthma underwent methacholine provocation (Visit 1) and sham challenge with isotonic saline (Visit 2). At Visit 1, exhaled air was repetitively collected pre-challenge, after reaching the provocative concentration (PC(20)) causing 20% fall in forced expiratory volume in 1 second (FEV(1)) and after subsequent salbutamol inhalation. At Visit 2, breath was collected pre-challenge, post-saline and post-salbutamol. At each occasion, an expiratory vital capacity was collected after 5 min of tidal breathing through an inspiratory VOC-filter in a Tedlar bag and sampled by electronic nose (Cyranose 320). Breathprints were analyzed with principal component analysis and individual factors were compared with mixed model analysis followed by pairwise comparisons. Inhalation of methacholine led to a 30.8 ± 3.3% fall in FEV(1) and was followed by a significant change in breathprint (p = 0.04). Saline inhalation did not induce a significant change in FEV(1), but altered the breathprint (p = 0.01). However, the breathprint obtained after the methacholine provocation was not significantly different from that after saline challenge (p = 0.27). The molecular profile of exhaled air in patients with asthma is altered by nebulized aerosols, but is not affected by acute changes in airway caliber. Our data demonstrate that breathprints by electronic nose are not confounded by the level of airway obstruction.
Related Concept Videos
Asthma I: Introduction
Asthma III: Clinical Manifestations
Inhaled Medications
Asthma-I: Introduction
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Chronic Obstructive Pulmonary Disease III: Chronic Bronchitis Features

