Volume fraction determination of binary liquid mixtures by measurement of the equalization wavelength

Ivan Martincek1, Dusan Pudis, Daniel Kacik

  • 1Department of Physics, University of Žilina, Univerzitná 1, SK- 01026, Žilina, Slovakia. ivmar@fel.uniza.sk

Related Concept Videos

Distillation: Vapor–Liquid Equilibria01:01

Distillation: Vapor–Liquid Equilibria

Distillation is a separation technique that takes advantage of the boiling point properties of disparate elements in a mixture. To perform distillation, we begin by heating a miscible mixture of two liquids with a significant difference in boiling points (at least 20°C). As the solution heats up and reaches the bubble point of the more volatile component, some molecules of the more volatile component transition into the gas phase and travel upward into the condenser, which is a glass tube with...
UV–Vis Spectroscopy: Beer–Lambert Law01:09

UV–Vis Spectroscopy: Beer–Lambert Law

The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The modern...
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Subcellular Fractionation01:32

Subcellular Fractionation

The homogenate obtained after cell lysis contains various membrane-bound organelles that can be further separated into pure fractions by subcellular fractionation. These isolates are used to study specific cellular components, analyze localized protein activity, and are even employed in diagnostics. Fractionation is typically achieved using centrifugation methods, the most common being density-gradient and differential centrifugation.
Differential Centrifugation
Differential centrifugation is...
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...