Related Experiment Video
Updated: May 26, 2026

Defining Substrate Specificities for Lipase and Phospholipase Candidates
Published on: November 23, 2016
An efficient hydrophilic interaction liquid chromatography separation of 7 phospholipid classes based on a diol
Chao Zhu1, Adrie Dane, Gerwin Spijksma
1School of Pharmacy, East China University of Science and Technology, 200237 Shanghai, China.
Abstract:
A hydrophilic interaction liquid chromatography (HILIC) - ion trap mass spectrometry method was developed for separation of a wide range of phospholipids. A diol column which is often used with normal phase chromatography was adapted to separate different phospholipid classes in HILIC mode using a mobile phase system consisting of acetonitrile, water, ammonium formate and formic acid. An efficient between-class separation of seven phospholipid classes including phosphatidylglycerol, phosphatidylethanolamine, phosphatidylinostol, phosphatidylcholine, phosphatidylserine, sphingomyelin and lysophosphatidylcholine was successfully achieved within 14 min using a gradient elution which starts with 90% of organic solvent and ends with 70% of organic solvent. 53 mM formic acid (in both organic phase and aqueous phase) and 60mM ammonium formate (only in aqueous phase) were used as mobile phase modifier. The relatively high amount of ammonium formate was essential to obtain well-shaped peaks of each phospholipid class, especially phosphatidylserines; actually, no negative effect due to ammonium formate was observed for electrospray-mass spectrometry detection in real-life samples. Good chromatographic separation between different lipid classes was obtained (Rs, from 0.73 to 4.97) and well-shaped peaks (tailing factor, from 0.98 to 1.20) were obtained. The developed method was fully validated and the satisfactory performance characteristics such as linearity (R(2), 0.990-0.999), retention time stability (RSD<1%), within day repeatability (RSD, 5-13%), between day variation (RSD, 7-14%) and recoveries (99.6-115.5%) indicated the gradient HILIC method was appropriate for profiling of plasma phospholipids. The method was successfully applied to separate phospholipids extracts from human plasma, mouse plasma and rat plasma.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
