Related Experiment Video
Updated: May 26, 2026

Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Endothelial dysfunction assessed by brachial artery ultrasound in severe sepsis and septic shock
Leandro Becker1, Karen Prado, Murilo Foppa
1Post-Graduate Program in Health Sciences, Cardiology and Cardiovascular Sciences, Medical School from Rio Grande doSul Federal University, Alegre, Brasil. lqbecker@terra.com.br
Purpose:
Noninvasive evaluation of endothelial function may be accomplished by ultrasound assessment of flow-mediated vasodilation (FMD) of the brachial artery. This study aims to investigate the role of FMD analysis on intrahospital prognosis of patients with sepsis.
Methods:
Adult patients admitted to the intensive care unit with severe sepsis or septic shock were consecutively included. Brachial artery FMD was measured upon admission, after 24 and 72 hours. A group of apparently healthy subjects paired for sex and age was used as controls. Patients were followed up to discharge or death.
Results:
We studied 42 patients (mean age, 51 ± 19 years) with sepsis predominantly of abdominal or respiratory etiology (75%). Acute Physiology And Chronic Health Evaluation II risk score was 23 ± 7, and intrahospital mortality rate was 33%. Flow-mediated vasodilation in septic patients was significantly lower than in healthy controls (1.5 ± 7% vs 6 ± 4%, P < .001). Most of the nonsurvivors (86%) showed a decline in sequential FMD analyses, whereas only 43% of survivors showed a reduction of FMD (P = .01). In nonsurvivors, FMD was significantly lower 72 hours after sepsis onset (-3.3% ± 10% vs 5.2% ± 4%; P < .05; time-group interaction P value = .03).
Conclusions:
Brachial FMD is altered in septic patients with hemodynamic instability, and its deterioration may be an early marker of unfavorable prognosis.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: