Related Experiment Video
Updated: May 26, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Two-stage cementless revision of late total hip arthroplasty infection using a premanufactured spacer
Daniel R P Neumann1, Thomas Hofstaedter, Corina List
1Orthopedic University Clinic, PMU Salzburg, Austria.
Abstract:
We observed 44 patients with 2-stage revisions for septic hip prostheses. We used a uniform protocol consisting of the implantation of a preformed spacer (interval 12-26 weeks), specific systemic antibiotic therapies, and cementless total hip arthroplasty at time of reimplantation. The minimum follow-up was 36 months (mean, 67 months; range, 36-120 months). During the spacer period, we observed 4 dislocations and 2 fractures leading to a resection arthroplasty interval before reimplantation in 5 cases. In one patient, reinfection was diagnosed 12 months after reimplantation. The Harris hip score increased from a preoperative mean of 39 to 90 at a mean follow-up of 67 months after reimplantation.