One-way valve bottle contamination rates in the immediate post-functional endoscopic sinus surgery period
Jennifer M Kofonow1, Aditi Bhuskute, Laurel Doghramji
1Department of Otorhinolaryngology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA.
Background:
Sinonasal saline irrigation has become an accepted practice in the immediate postoperative management of functional endoscopic sinus surgery (FESS) patients. Recent studies have found that valveless delivery systems of sinonasal irrigation are colonized with bacteria. An alternative delivery system uses a one-way valve to reduce saline backflow and may limit bottle contamination. Our sole objective was to determine whether this system in post-FESS patients eliminates microbial bottle contamination.
Methods:
Eight patients undergoing FESS were given one-way valve irrigation bottles to use immediately after surgery. Bottles were collected after 1 week of use and another set of bottles after an additional week. Endoscopic-directed cultures of the middle meatus were performed at the time of surgery. Returned used bottles were swabbed for bacteria and the valve system of the bottle was analyzed under scanning electron microscopy (SEM) for the presence of bacteria.
Results:
All sinus swabs collected at the time of surgery grew bacteria with Staphylococcus sp. present in all samples. After the 1st week of use, 5/8 bottles grew bacterial cultures and showed bacterial presence on the valves by SEM. After the 2nd week, 4/5 bottles had positive culture results and also showed bacterial presence on the valves by SEM.
Conclusion:
Despite commercial claims that the use of valves and limit of backflow into the bottle will eliminate contamination, our study showed that one-way valve delivery systems become contaminated with bacteria after 1 week of use. We also showed that the bottle valves themselves harbor bacteria after 1 week of use.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...