Related Experiment Video
Updated: May 26, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Effects of different cavity disinfectants on shear bond strength of a silorane-based resin composite
Soley Arslan1, A Ruya Yazici, Jale Gorucu
1Department of Restorative Dentistry and Endodontics, School of Dentistry, Erciyes University, Kayseri, Turkey.
Aim:
This in vitro study evaluated the effect of different cavity disinfection agents on bond strength of a silorane-based resin composite.
Materials And Methods:
Thirty-six caries-free human third mandibular molars sectioned in mesio-distal direction were mounted in acrylic resin with their flat dentin surfaces exposed. After the dentin surfaces were wet ground with # 600 silicon carbide paper, the teeth were randomly divided into 6 groups of 12 each according to the cavity disinfection agents; chlorhexidine (CHX); sodium hypochlorite (NaOCl), propolis, ozone, Er,Cr:YSGG laser and no treatment (control). After treatment of dentin surfaces with one of these cavity disinfection agents, Filtek Silorane adhesive system was applied. The silorane-based resin composite, Filtek Silorane was condensed into a mold and polymerized. After storage at 37°C for 24 hours, the specimens were tested in shear mode at a crosshead speed of 1.0 mm/minute. The results were analyzed by one-way ANOVA.
Results:
No statistically significant difference was observed between the groups (p>0.05).
Conclusion:
The use of the tested cavity disinfection agents, chlorhexidine, sodium hypochlorite, propolis, ozone and Er,Cr:YSGG laser did not significantly affect the dentin bond strength of a silorane-based resin composite, filtek supreme.
Clinical Significance:
Cavity disinfectant applications did not affect the dentin bond strength of a silorane-based resin composite.