Related Experiment Video
Updated: May 26, 2026

Seeding and Implantation of a Biosynthetic Tissue-engineered Tracheal Graft in a Mouse Model
Published on: April 1, 2019
Endoscopic closure of a tracheal access site using bioglue after transtracheal thoracoscopy in a nonsurvival canine
1Laboratory Animal Center, Department of Surgery, Chang Gung Memorial Hospital, Linko, Chang Gung University, Guei-Shan Shiang, Taiwan, ROC.
Objectives:
An ideal wound closure device would repair the wound with minimal complexity. In this report, we describe a simple wound closure method using BioGlue sealant.
Method:
Eleven canines underwent transtracheal pericardial window creation under endoscopic guidance for natural orifice transluminal endoscopic surgery (NOTES). The tracheal wound was closed using BioGlue sealant. The integrity of the wound was assessed by determining the amount of air leaking under mechanical ventilation.
Results:
Transtracheal thoracic exploration and pericardial window creation was successful for all of the canines, and adequate wound closure was achieved in 10 of the canines. There was 1 case of NOTES-related death arising from misplacement of the endotracheal tube in the left lower lobar bronchus. This caused a collapse of the left upper lobe and ventilatory failure. Minor lung injuries occurred in 3 canines and minor mediastinal bleeding was encountered in 1 canine during the creation of the access site.
Conclusion:
BioGlue sealant was found to be effective in sealing the tracheal wound in all but 1 of the canines. This study demonstrates that the use of the sealant is a simple and efficient means of endoscopically closing the tracheal access site in NOTES.
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques