Bubble vs conventional continuous positive airway pressure for prevention of extubation failure in preterm very low
Sucheta Yadav1, Anu Thukral, M Jeeva Sankar
1Department of Pediatrics WHO Collaborating Centre for Training and Research in Newborn Care, All India Institute of Medical Sciences, New Delhi, India.
Objective:
To compare the efficacy of bubble and conventional nasal continuous positive airway pressure (CPAP) in preventing extubation failure (EF) in preterm infants.
Methods:
Infants of gestation ≤32 wk and birth weight <1500 g, ready for initial extubation within first wk of life were randomly allocated to either bubble (n = 16) or conventional (n = 16) CPAP. A standardized protocol was used for extubation. Bubble CPAP was delivered by Fischer and Paykel equipment using short binasal prongs and conventional CPAP was delivered by a ventilator using Argyle short binasal prongs. CPAP was initiated at a pressure of 4-6 cm of H(2)O and FiO(2) of 0.4-0.5 and adjusted to maintain normal saturation (90-93%) and comfortable breathing. Primary outcome was EF, defined as need for mechanical ventilation within 72 h of extubation.
Results:
Baseline characteristics including birth weight (g; 1027 ± 243 vs. 1018 ± 227; p = 0.83), gestation (wk; 28.7 ± 1.8 vs. 28.4 ± 1.6; p = 0.30), infants <28 wk gestation (6 vs. 7, p = 0.72) were comparable between the two groups. Respiratory distress syndrome was the indication for ventilation in 13 (81%) and 14 (87%) infants on bubble CPAP and conventional CPAP groups respectively. (p = 0.99). There was no difference in the EF rates between the bubble (n = 4) and conventional CPAP (n = 9) groups. (RR 0.49; 95% CI 0.20-1.2; p = 0.14). Median time to extubation failure was also comparable between the two groups (h; median [range]: 29 [14-49] vs. 17 [7-28]; p = 0.35).
Conclusions:
The possibility that bubble CPAP may be associated with reduced EF as suggested in this pilot study requires further investigation in an adequately powered multicentric study.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...