Related Experiment Video
Updated: May 26, 2026

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Noncontact common-path Fourier domain optical coherence tomography method for in vitro intraocular lens power
Yong Huang1, Kang Zhang, Jin U Kang
1U.S. Food and Drug Administration, Center for Devices and Radiological Health, 10903 New Hampshire Avenue, Silver Spring, Maryland 20993, USA. yhuang60@jhu.edu
Abstract:
We propose a novel common-path Fourier domain optical coherence tomography (CP-FD-OCT) method for noncontact, accurate, and objective in vitro measurement of the dioptric power of intraocular lenses (IOLs) implants. The CP-FD-OCT method principle of operation is based on simple two-dimensional scanning common-path Fourier domain optical coherence tomography. By reconstructing the anterior and posterior IOL surfaces, the radii of the two surfaces, and thus the IOL dioptric power are determined. The CP-FD-OCT design provides high accuracy of IOL surface reconstruction. The axial position detection accuracy is calibrated at 1.22 μm in balanced saline solution used for simulation of in situ conditions. The lateral sampling rate is controlled by the step size of linear scanning systems. IOL samples with labeled dioptric power in the low-power (5D), mid-power (20D and 22D), and high-power (36D) ranges under in situ conditions are tested. We obtained a mean power of 4.95/20.11/22.09/36.25 D with high levels of repeatability estimated by a standard deviation of 0.10/0.18/0.2/0.58 D and a relative error of 2/0.9/0.9/1.6%, based on five measurements for each IOL respectively. The new CP-FD-OCT method provides an independent source of IOL power measurement data as well as information for evaluating other optical properties of IOLs such as refractive index, central thickness, and aberrations.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...