Related Experiment Videos
[Corrosion resistance and bond strength of dental alloys]
1Universitätsklinik und Poliklinik für Zahn-, Mund und Kieferkrankheiten, Köln.
ZWR
|July 1, 1990
Abstract:
Investigated Ni-alloys, which showed extensive solubility of Ni particles in corrosion bathes due to DIN 13927, also revealed pronounced lost of bond strength to ceramic veneers when immersed into corrosion bathes of equal constitution. Noble metal alloys with a gold concentration more than 50 percent, however, showed no such large lost of bond strength. Pd alloys showed a lost of bond strength which increased with their Ga concentration. Co alloys revealed a behavior similar to the Ni alloys but with no obvious correlation between solubility and lost of bond strength.