High-resolution mass spectrometry for integrated qualitative and quantitative analysis of pharmaceuticals in
Gérard Hopfgartner1, David Tonoli, Emmanuel Varesio
1Life Sciences Mass Spectrometry, School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Quai Ernest-Ansermet, 30, 1211 Geneva 4, Switzerland. gerard.hopfgartner@unige.ch
Abstract:
Quantitative and qualitative high-resolution (HR) dependent and independent acquisition schemes on a QqTOF MS (with resolving power 20,000-40,000) were investigated for the analysis of pharmaceutical compounds in biological fluids. High-resolution selected reaction monitoring (HR-SRM) was found to be linear over three orders of magnitude for quantitative analysis of paracetamol in human plasma, offering a real alternative to triple quadrupole LC-SRM/MS. Metabolic stability of talinolol in microsomes was characterized by use of three different acquisition schemes: (i) information-dependent acquisition (IDA) with a TOF MS experiment as survey scan and product-ion scan as dependent scan; (ii) MS(ALL) by collecting TOF mass spectra with and without fragmentation by alternating the collision energy of the collision cell between a low (i.e., 10 eV) and high setting (i.e., 40 eV); and (iii) a novel independent acquisition mode referred to as "sequential window acquisition of all theoretical fragment-ion spectra" (SWATH) or "global precursor ions scan mode" (GPS) in which sequential precursor ions windows (typically 20 u) are used to collect the same spectrum precursor and fragment ions using a collision energy range. SWATH or GPS was found to be superior to IDA or MS(ALL) in combination with UHPLC for qualitative analysis but requires a rapidly acquiring mass spectrometer. Finally, the GPS concept was used for QUAL/QUAN analysis (i.e. integration of qualitative and quantitative analysis) of bosentan and its metabolites in urine over a concentration range from 5 to 2,500 ng mL(-1).
Related Concept Videos
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Matrix-Assisted Laser Desorption Ionization (MALDI)
Mass Spectrum: Interpretation


